Class ResDi
Version 1.0
Modified 08-MAR-2026 11:05:32.00
Code rt_plc_macro_io.h
 Reset Digital input.

 If the input signal is TRUE, the specified local
 Di-signal is cleared at the execution, otherwise there
 will be no effect on the Di-signal.

 The complete name of the Di object has to be supplied;
 its last segment is shown in the right empty part of
 the symbol.

Note!
 This object is used for simulation purposes.
 SimulFlag will be set TRUE and ReadWriteFlag FALSE
 in the IOHandler object, i.e. any physical I/O-hardware may
 not be used on the node in connection to this object.

RtBody attributes pwr_sClass_resdi
Boolean In in The input is connected to a binary signal or left open.
In the latter case In is default TRUE and the condition
not adjustable in the run time system, and consequently
the function is unconditional.
Specifies whether the Di-signal should be cleared or
not. FALSE means that the signal is not effected, and
TRUE means that a local Di-signal is reset.

DevBody attributes 
AttrRef DiObject In Specifies the complete name of the Di object. Used by
the PLC Editor.
AttrRef SigChanCon   Used by the PLC Editor.
Int32 DiObjectSegments   Specifies how many segments of the Di object name that
is to be displayed in the symbol of the ResDi object.
The segments are counted from behind.
0 and 1 both result in displaying the last segment of
the signal object name.
Boolean ShowSigChanCon   Specifies if the name on the channel object (
associated with the signal object) is to be displayed
in the symbol of the ResDi object or not. FALSE means
no displaying and TRUE displaying.

See also SigChanConSegments.
Int32 SigChanConSegments   Specifies, when ShowSigChanCon = TRUE, how many
segments of the channel object name that is to be
displayed in the symbol of the ResDi object. The
segments are counted from behind.

0 and 1 both result in displaying the last segment of
the channel object name.
PlcNode PlcNode  


GraphPlcNode
object_type 116
parameters[0] 1
parameters[1] 0
parameters[2] 0
parameters[3] 0
subwindows 0
graphmethod 7 (Get,Set)
graphindex 1
default_mask[0] 1
default_mask[1] 0
segname_annotation 0
devbody_annotation 1
compmethod 38
compindex 0
tracemethod 1
traceindex 1
connectmethod 1
executeordermethod 6
objname ResDi
graphname ResDi
debugpar In


Template Object
In 1


Attributes detail


In Input
Class Input
Type Boolean
Flags STATE | RTVIRTUAL | DEVBODYREF | NOEDIT
GraphName in
Body RtBody
 The input is connected to a binary signal or left open.
 In the latter case In is default TRUE and the condition
 not adjustable in the run time system, and consequently
 the function is unconditional.
 Specifies whether the Di-signal should be cleared or
 not. FALSE means that the signal is not effected, and
 TRUE means that a local Di-signal is reset.

DiObject Intern
Class Intern
Type AttrRef
Flags
GraphName In
Body DevBody
 Specifies the complete name of the Di object. Used by
 the PLC Editor.

SigChanCon Intern
Class Intern
Type AttrRef
Flags INVISIBLE
Body DevBody
 Used by the PLC Editor.

DiObjectSegments Intern
Class Intern
Type Int32
Flags
Body DevBody
 Specifies how many segments of the Di object name that
 is to be displayed in the symbol of the ResDi object.
 The segments are counted from behind.
 0 and 1 both result in displaying the last segment of
 the signal object name.

ShowSigChanCon Intern
Class Intern
Type Boolean
Flags
Body DevBody
 Specifies if the name on the channel object (
 associated with the signal object) is to be displayed
 in the symbol of the ResDi object or not. FALSE means
 no displaying and TRUE displaying.

 See also SigChanConSegments.

SigChanConSegments Intern
Class Intern
Type Int32
Flags
Body DevBody
 Specifies, when ShowSigChanCon = TRUE, how many
 segments of the channel object name that is to be
 displayed in the symbol of the ResDi object. The
 segments are counted from behind.

 0 and 1 both result in displaying the last segment of
 the channel object name.

PlcNode Buffer
Class Buffer
Type PlcNode
Flags INVISIBLE
Body DevBody